4 step verification function, Step verification function, Setting the step verification function – KEYENCE DV-90 User Manual
Page 77: Step verification function -17
4-17
E DV-90-IM
4
Ba
si
c
Func
tions
4-4
Step Verification Function
This function is used to verify two codes and determine if they match.
Step Verification Function
The step verification function verifies two data items read sequentially.
For example, when the first reading is “12345” and the second is “12345”, “OK” is output. How-
ever, if the first reading is “51266” and the second is “12345”, “NG” is output.
The operation flow for working with the step verification function is as follows.
1 Setting the step verification function
2 Working with the step verification function
Step Verification mode does not require data to be preset before scanning.
Setting the Step Verification Function
1
Move to the setting mode.
Press the
key for one second. The display
enters the setting mode.
2
Displaying the basic settings menu.
Place the cursor on “Main” by pressing the
or
key. Then, press the
key.
3
Specify the verification type.
Display “Verify Type” by pressing the
or
key. Then, press the
key.
1 2 3 4 5
1 2 3 4 5 . . . . . . . . . . . . O K (matched)
5 1 2 6 6
1 2 3 4 5 . . . . . . . . . . . . N G (not matched)
6 6 6 6 6
6 6 6 6 6 . . . . . . . . . . . . O K (matched)
First reading
Second reading
First reading
Second reading
First reading
Second reading
M a i n
2
V e r i f y
MENU
0 1
V e r i f y T y p e
0 : N o r m a l
0 : N o r m a l
V e r i f y T y p e
0 1