3 setting procedure, Basic settings, Setting procedure -7 basic settings -7 – KEYENCE DV-90 User Manual
Page 145: Setting procedure -7, Setting procedure
7-7
E DV-90-IM
7
How to Use the Setup
So
ftw
a
re
7-3
Setting Procedure
The SetUp Software performs various settings required for using the DV-90.
This section describes the operations of the SetUp Software. For the functions and setting contents, refer to the
corresponding pages.
Basic Settings
The units to be connected to the DV-90 and the verification type are set in the Basic Settings.
The setting items are selected from the pull-down menu.
Verify Pattern
PORT2 Connect Unit
PORT1 Connect Unit
PORT2 Type
PORT1 Type
• Verify Pattern
Sets the verification mode.
(
Refer to 4-2)
Normal
Active
Step
3Points-A
3Points-B
• PORT1 Connect Unit
Sets the unit to be connected to PORT1.
None
Code Reader
• PORT1 Type
Sets the type of code reader to be con-
nected to PORT1. This cannot be set
when “PORT1 Connect Unit” is set to
“None”.
TypeA…BL-1300/700/600/180 Series
TypeB…HR-50RK/40RK/UC51, BL-N70RKE/N9R
TypeC…TL-800, TL-70R
TypeD…BL-210RK
TypeE…SR-D100/750/600 Series,
HR-100 Series
Others…Other code readers
• PORT2 Connect Unit
Sets the unit to be connected to
PORT2.
None
PC
PLC Link
Code Reader
• PORT2 Type
When “PORT2 Connect Unit” is set to
None or PC, this function is not avail-
able.
When set to PLC Link, choose from:
(
Refer to 9-2)
KEYENCE KV
MELSEC
SYSMAC
When set to Code Reader, choose from:
TypeA…BL-1300/700/600/180 Series
TypeB…HR-50RK/40RK/UC51, BL-N70RKE/N9R
TypeC…TL-800, TL-70R
TypeD…BL-210RK
TypeE…SR-D100/750/600 Series,
HR-100 Series
Other…Other code readers