3 active verification, Active verification function, Setting the active verification function – KEYENCE DV-90 User Manual
Page 73: Active verification -13, Active verification
4-13
E DV-90-IM
4
Ba
si
c
Func
tions
4-3
Active Verification
This function is used to select only one preset from the registered master data, and to confirm if the read data
matches it.
Active Verification Function
With the normal verification function, the read data is checked with all preset master data. With the
active verification function, you select only one preset (active record) from the master data to com-
pare to.
The operation flow for working with the active verification function is as follows.
1 Setting the active verification function.
2 Presetting the master data
3 Selecting the active record number
4 Working with the active verification function
Setting the Active Verification Function
1
Move to the setting mode.
Press the
key for one second. The display
enters the setting mode.
2
Displaying the basic settings menu.
Place the cursor on “Main” by pressing the
or
key. Then, press the
key.
3
Specify the verification type.
Display “Verify Type” by pressing the
or
key. Then, press the
key.
Read data
Master data
Matched to active record
Unmatched to active record
NG
NG
NG
OK
222222
333333
555555
111111
Unmatched to active record
Unmatched to active record
M a i n
2
V e r i f y
MENU
0 1
V e r i f y T y p e
0 : N o r m a l
0 : N o r m a l
V e r i f y T y p e
0 1