KEYENCE DV-90 User Manual

Page 205

background image

9-5

9

E DV-90-IM

PLC Link

9-2 Device Assignment

The area in which the data is written is assigned as follows with the “Write head address” specified
in “X+01 to +03” at the heads (Y1 to Y3).

DM

Description

Data description

Writing from

the DV-90

Writing from

the PLC

X+13

Reset Occurrence Detection flag

0: No reset

1: Reset occurred

Yes

(0

→1)

Yes

(1

→0)

X+14

Interlock Release Notice Flag

0: Interlock not released

1: Interlock released

Yes

(1

→0)

Yes

(0

→1)

X+15 to +16

Reserved Area

X+17

Operation Status Check Area

0: Non-access state

1: During normal operation

2: During another operation

3: Interlocked

4: Work standby

Yes No

X+18

Read Number Check Area

1: First data reading

2: Second data reading

3: Third data reading

Yes No

X+19

Verify Count Value Check Area

0 to 65535

Yes

No

X+20

Record Number Check Area

1 to 900: Record number

0: Verify Step OK

999: Verify NG

998: Selected Master Verify NG

997: Read Error

Yes No

X+21

Output Number Check Area

1 to 900: Output number

0: Verify Step OK

999: Verify NG

998: Selected Master Verify NG

997: Read Error

Yes No

X+22

Read Quality Check Area

0: Read Quality OK

1: Read Quality NG

Yes No

X+23 to +25

Reserved Area

DM

Description

Data description

Writing from

the DV-90

Writing from

the PLC

Y1+00

Data 1 Number of Digits Check

Area

1 to 100: Number of digits of

Data 1

Yes

No

Y1+01 to +50

Data 1 Check Area

Data 1 content

Yes

No

Y2+00

Data 2 Number of Digits Check

Area

1 to 100: Number of digits of

Data 2

Yes No

Y2+01 to +50

Data 2 Check Area

Data 2 content

Yes

No

Y3+00

Data 3 Number of Digits Check

Area

1 to 100: Number of digits of

Data 3

Yes No

Y3+01 to +50

Data 3 Check Area

Data 3 content

Yes

No