beautypg.com

KEYENCE DV-90 User Manual

Page 110

background image

5-12

E DV-90-IM

5

Ex
tend

ed Fun

c

tions

5-4 Verify Limitation Function

„ Checking the commodity code and expiration date of an GS1-128 code using a differ-

ent format

When multiple formats are used in the GS1-128 code, the master data used to check the commodity
code and the expiration date is as follows.
The expiration date can be checked when the upper and lower limit values of the expiration date are
set in Master data 2 and 3.

Note

• Input the symbol “ ^ ” to preset the GS with the SetUp Software. Send the GS , when pre-

setting the data by the serial communication command.

• The GS is displayed as “

” in the display of the DV-90.

• It is not possible to input the GS when editing the master data by key operation in the pre-

set mode.

01 14512345678903 17 041215 30 1000 GS 10 1234

Commodity code Expiration date Quantity Lot number

01 54512345678901 30 1000 GS 10 1234 GS 041215

Commodity code Quantity Lot number Expiration date

* GS is the character used to represent the data delimitation (1Dh), which is counted as one digit.

Record

Number

Output

Number

Master data 1

Master data 2

Master data 3

1

1

1451234

5678903

+00030

+00060

Digit

Limit Direction : Forward

Limit Start : 3

Limit Digits : 14

Date Compare

Limit Direction : Forward

Limit Start : 19

(Limit Digits : 6)

Compare Logic :

Date Compare

Limit Direction : Forward

Limit Start : 19

(Limit Digits : 6)

Compare Logic :

2

2

5451234

5678901

+00030

+00030

Digit

Limit Direction : Forward

Limit Start : 3

Limit Digits : 14

Date Compare

Limit Direction : Forward

Limit Start : 19

(Limit Digits : 6)

Compare Logic :

Date Compare

Limit Direction : Forward

Limit Start : 19

(Limit Digits : 6)

Compare Logic :

...

..

..

...

..

..

..

..

...

..

..

...

..

..

...

.

Lower limit value

Upper limit value