Control of the read trigger

Input 0000 controls the read trigger.

Data read process

• When the “Write Complete Confirmation Flag”

displays “1: Data Write Complete”, it starts pro-
cessing the written data. After the process is
completed, each flag is initialized.

* DM0010 is valid only in “Sequence processing”.

Select active record

Set the Active record number to 1 from Input 0001.

Set the Active record number to 2 from Input 0002.

@MOV

0002

#0000

DM0011

@MOV

&2

DM0012

@MOV

0001

#0000

DM0011

@MOV

&1

DM0012

0000

#0001

DM0006

0000

@MOV

@MOV

#0000

DM0006

25313

CMP

DM0009

#0001

Continue to the next page

MOV

25506

#0000

DM0009

MOV

#0001

DM0010

This processes

data programs

written in DM100

and later.