beautypg.com

KEYENCE DV-90 User Manual

Page 43

background image

3-9

3

C

on
necti

ons

and

M
ounti

ng

E DV-90-IM

„ Connecting the BL-1300 Series or the SR-600/500 Series

To connect the BL-1300 Series or the SR-600/500 Series, use the OP-80616 conversion cable.

„ Connecting the N-400 or N-410

Connecting the BL-U1

„ Connecting the N-R2 or BL-U2

If you do not want to connect the photoelectric switch for the trigger input (timing input)
directly to each one of the BL-U1, BL-U2, N-R2, N-400 and N-410 (in multiple head mode),
but want to connect it to the trigger input terminal on the DV-90, set the setting of the “Trig-
ger Mode” of PORT1/2 to “Software”. For the setting of “Trigger Mode”, refer to page 6-9.

BL-1300 or SR-600/500

The cable length of OP-80616 is 200 mm.

12-pin round

(female)

9-pin D-sub

(female)

# 4-40 screw

Connector case

• In the output terminal setting

on the BL-1300 Series and the
SR-600 Series, set OUT1 to
OK and OUT2 to NG+ERROR.

• On the SR-500 Series, set as

“NG is output when the read
error occurs”.

The connections can be established via the optional
cable OP-22149 (1.5m) and the conversion con-
necter OP-25057.

The connections can be established via the optional
cable OP-29860 (1.5 m).

Connector case

Connector case

25-pin D-sub

(male)

M2.6 screw

9-pin D-sub

(female)

# 4-40 screw

25-pin D-sub

(male)

M2.6 screw

9-pin D-sub

(female)

# 4-40 screw

N-R2 or BL-U2

The connections can be established via the optional
cable OP-29859 (1.5 m).

Connector case

Connector case

25-pin D-sub

(female)

M2.6 screw

9-pin D-sub

(female)

# 4-40 screw

3-2 RS-232C Interface Connection