8-3 Command Communication Details

Setting Command Description

„ End/Initialization of the setting mode

„ Settings relevant to verification function

Function

Sending command

Response

Notes

Setting mode end

CEND

OK

Ends the setting mode.

Initialize all settings

DFLT

OK

Initializes all settings (operation settings, master

table).

Master table initialization DFLM

OK

Initializes the master table. The counter is initialized

at the same time.

Counter initialization

DFLC

OK

Initializes the counters of all the records.

Function

Sending command

Response

Notes

Verify Type

Important: The

master table is

initialized when

Verify Type is

changed.

Change

WRB0n

OK

n = 0: Normal verification

1: Active verification

2: Step verification

3: 3 point-A verification

4: 3-point-B verification

5: 2-point verification

Check

RDB0 n

Parallel Out

Change

WRB1n

OK

n = 0: Off

1: Bit

2: Binary

3: BCD

Check

RDB1

n

Interlock

Change

WRB2n

OK

n = 0: Off

1: Interlock occurs at Verify OK

2: Interlock occurs at Verify NG

3: Interlock occurs at Read Error

Check

RDB2

n

Counter

Change

WRB3n

OK

n = 0: OFF

1: ON

Check

RDB3 n

Reference Data

Change

WRB4n

OK

n = 0: OFF

1: ON

Check

RDB4

n

Communication

Protocol

Change

WRB5n

OK

n = 0: No Handshaking

1: PASS/RTRY protocol

2: ACK/NAK protocol

Check

RDB5

n

USB Data Output

Change

WRB6n

OK

n = 0: OFF

1: ON

Check

RDB6

n

Master Limit Number Change

WRB7nnn

OK

nnn = 001 through 900

Check

RDB7

nnn