beautypg.com

2 normal verification, Normal verification function, Setting the normal verification function – KEYENCE DV-90 User Manual

Page 64: Normal verification -4, Normal verification

background image

4-4

E DV-90-IM

4

Ba
si

c

Func

tions

4-2

Normal Verification

This is used to compare and verify the master data, which is registered (preset) beforehand, to read code data.

Normal Verification Function

The normal verification function is used to compare and verify the master data, which is registered
(preset) beforehand, to read data with the code reader.
The DV-90 holds 900 master data items at maximum, and compares and verifies master data with
read data. The results can be output from the 12-bit parallel output terminals. The DV-90 can output
the number that corresponds to the matched master data as bits, binary digits or BCD.

The operation flow for working with the normal verification function is as follows.

1 Setting the normal verification function
2 Presetting the master data
3 Working with the normal verification function

Setting the Normal Verification Function

1

Move to the setting mode.

Press the

key for one second. The display

enters the setting mode.

2

Display the basic settings menu.

Place the cursor on “Main” by pressing the

or

key. Then, press the

key.

3

Specify the verification type.

Display “Verify Type” by pressing the

or

key. Then, press the

key.

Read data

Master data

Matched

Unmatched

NG

OK

OK

OK

111111

222222

333333

444444

111111

222222

333333

555555

Matched

Matched

M a i n

2

V e r i f y

MENU

0 1

V e r i f y T y p e

0 : N o r m a l

0 : N o r m a l

V e r i f y T y p e

0 1