KEYENCE DV-90 User Manual
Page 83

4-23
4
E DV-90-IM
Ba
si
c
Func
tions
4-5 3-Point-A Verification Function
3
Read the second code (Master data 2)
with the code reader.
The buzzer is sounded, and the read data is pre-
set as Master data 2.
The LCD displays the destination to which
Master data 3 (M3) is registered.
4
Read the third code (Master data 3) with
the code reader.
The buzzer is sounded, and the read data is set
as Master data 3.
The LCD displays the destination to which
Master data 1 is registered for the next record
number.
5
Exit the preset mode.
Press the
key after presetting is completed. The preset LED is illuminated, and the preset
mode is terminated.
When Master data 1 to 3 are preset in Record numbers 1 to 3, the data is as shown below.
(Example data)
“Port number limitation” and “Reference data” are omitted from the above table.
When a format error occurs
Presetting the master data is completed.
Record number
Output number
Master data 1
Master data 2
Master data 3
1
1
AAA123
E555
HH50
2
2
BBB456
F666
H60
3
3
CCC789
G777
JJ70
Note
• The preset mode cannot be finished unless Master data 1 to 3 have all been preset.
(“Format Error” will be displayed.) Be sure to preset all of Master data 1 to 3.
When you want to exit the preset mode when Master data 1 to 3 have not been preset,
delete the preset data with the
key.
• After the master data is read, the record number is not automatically added if the auto
increment function is turned OFF.
• When a read error occurs, the read error code is preset if you are working with a fixed
code reader. In such a case, redo the preset.
M 3 :
( E M P T Y )
M 1 :
( E M P T Y )
PRESET
DEL