KEYENCE DV-90 User Manual
Page 232

9-32
E DV-90-IM
9
PLC Link
CQM1 (H), C200HS, C200HE, C200HG, C200HX (CPU internal port),
CQM1-SCB41, C200HW-COM02/04/05/06 (communication board)
(DIP switch)
(PC system setting)
* In the standard setting, the baud rate is set to 9600 bits/s, data length to 7, parity to even, and stop
bit length to 2. When you want to change the settings, set the bit to “1”, and configure the desired
settings in DM6646, DM6556, and DM6551.
SW number
Setting value
Setting content
5 OFF
Cancels the fixed settings of the communication port/communication condition
CPU internal
RS-232C port
Communication board
Bit
Setting item
DM value
DM6645
Port A: DM6555
Port B: DM6550
00 to 03
Communication condition setting
0: Standard setting *
0000
04 to 07
With or without CTS control
0: None
12 to 15
0: Upper link
DM6646
Port A: DM6556
Port B: DM6551
00 to 07
Communication speed
03: 9600
0303
08 to 15
Frame format
03: Data length: 7 bits, Parity: Even,
Stop: 2 bits
DM6647
Port A: DM6557
Port B: DM6552
00 to 15
Transmission delay time
(unit 10 ms)
0000
DM6648
Port A: DM6558
Port B: DM6553
00 to 07
Unit number
00
0000