beautypg.com

KEYENCE DV-90 User Manual

Page 232

background image

9-32

E DV-90-IM

9

PLC Link

9-5 Settings

„ CQM1 (H), C200HS, C200HE, C200HG, C200HX (CPU internal port),

CQM1-SCB41, C200HW-COM02/04/05/06 (communication board)
(DIP switch)

(PC system setting)

* In the standard setting, the baud rate is set to 9600 bits/s, data length to 7, parity to even, and stop

bit length to 2. When you want to change the settings, set the bit to “1”, and configure the desired
settings in DM6646, DM6556, and DM6551.

SW number

Setting value

Setting content

5 OFF

Cancels the fixed settings of the communication port/communication condition

CPU internal

RS-232C port

Communication board

Bit

Setting item

DM value

DM6645

Port A: DM6555

Port B: DM6550

00 to 03

Communication condition setting
0: Standard setting *

0000

04 to 07

With or without CTS control
0: None

12 to 15

0: Upper link

DM6646

Port A: DM6556

Port B: DM6551

00 to 07

Communication speed
03: 9600

0303

08 to 15

Frame format
03: Data length: 7 bits, Parity: Even,
Stop: 2 bits

DM6647

Port A: DM6557

Port B: DM6552

00 to 15

Transmission delay time
(unit 10 ms)

0000

DM6648

Port A: DM6558

Port B: DM6553

00 to 07

Unit number
00

0000