4-3 Active Verification

4

Specify the active verification function

Place the cursor on “1: Active” by pressing the

and

key. Then, press the

key.

5

Exit the setting mode.

Press the

key twice.

Setting of the active verification function is completed.

Presetting the Master Data (Preset Mode)

The same procedure used when setting normal verification is used to preset the master data. (

Refer to 4-5)

Selecting the Active Record

Select the data to verify (active record) in the active verification function. The four methods for
selecting the active record are as follows:

(1) Via DV-90 panel buttons

Selects the active record from the DV-90 front panel.

(2) With the code reader

Selects the active record by reading the data with the code reader connected to the DV-90.

(3) By serial communication command

Selects the active record via serial commands. (

Refer to 8-11)

(4) By PLC link

Selects the active record using the PLC link. (

Refer to 9-4)

„ Via DV-90 panel buttons

This method is used to select the active record while viewing the record number.

1

Select the active record.

Select the record number by pressing the

or

key.

Note

The master table is initialized when the verification type is changed.
However, it is not initialized when active verification is changed to normal verification.

Note

• I/O cannot be used to select or change the active record.
• When you are using the PLC link, you cannot use methods (1) to (3).

0 1

V e r i f y T y p e

1 : x x x x x

ESC

1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7

M 1 :