Presetting the master data (preset mode), Presetting the master data (preset mode) -22 – KEYENCE DV-90 User Manual
Page 82

4-22
E DV-90-IM
4
Ba
si
c
Func
tions
4-5 3-Point-A Verification Function
3
Specify the verification type.
Display “Verify Type” by pressing the
or
key. Then, press the
key.
4
Specify the 3-point-A verification func-
tion.
Place the cursor on “3Points-A”. Then,
press the
key.
5
Exit the setting mode.
Press the
key twice.
Setting of the 3-point-A verification function is completed
Presetting the Master Data (Preset Mode)
Three preset master data items (Master data 1 to 3) are required to preset a record number.
1
Press the
key.
The preset LED is illuminated and thedisplay
moves to the preset mode. The record number
indictor LED shows “1”. “(EMPTY)” is dis-
played on the LCD, which indicates that Master
data 1 (M1) is not preset.
2
Read the first code (Master data 1) with
the code reader.
The buzzer is sounded, and the read data is set
as Master data 1.
The LCD displays the destination to which
Master data 2 (M2) is registered
Note
The master table is initialized when the verification type is changed.
However, the master table is not initialized when 3-point-B verification is changed to 3-
point-A verification.
0 : N o r m a l
V e r i f y T y p e
0 1
3 : 3 P o i n t s - A
V e r i f y T y p e
0 1
ESC
M 1 :
( E M P T Y )
OK
NG
PRESET
12
11
10
9
8
7
6
5
4
TRG1
TRG2
3
2
1
ERR
PRESET
M 2 :
( E M P T Y )