PLC Link

9-2 Device Assignment

„ DM that checks the current operation status

• The current operation status of the DV-90 can be checked.

• “0: Non-access state” is generated when PLC link communication cannot be established at

power-on, and the value of “X+17” in the PLC has not changed from the initial value “0”.
(“X+17” should be initialized to “0” when launching the program.) However, commu-
nication errors such as that caused by a cable breakage cannot be checked after communication
has been established.

DM

Description

Data description

Writing from

the DV-90

Writing from

the PLC

X+17

Operation Status Check Area

0: Non-access state

1: During normal operation

2: During another operation

3: Interlocked

4: Work standby

Yes No

Data description

Description

0: Non-access state

• State where the PLC link communication is not established.

1: During normal operation

• Operating in the verification mode

2: During another operation

• Operating in the operation mode other than the verification mode

• State where the send buffer over or receive buffer over has occurred in

the verification mode

3: Interlocked

• State where interlock is imposed.

4: Work standby

• State where “X+00 Work Start Flag” is not set to “1: Work start”.