6.6.5 RejectGateHandling function block
The RejectGateHandling function block can be used to open a reject gate. A switching delay
time is entered to compensate reject gate switching delays.
Task information
Can be called in:
Cyclic task
Time-controlled task
(INTERVAL)
Event-controlled task
(EVENT)
Interrupt task
Variable
names
Inputs
(Variable type: VAR_INPUT)
Name Data
type
Value/Meaning
dnSwitchingDwelltime
DINT
Entry indicating the switching delay time of the reject gate in ms
nNActXAxis_v
INT
Line speed of the x axis. The value can be positive or negative. Positive values are
interpreted as clockwise rotation and negative values as counter-clockwise rotation.
wMotionProfileAct
WORD
Motion profile currently in use. Connect this input to variable g_wMotionProfileAct.
wNumberOfRejectCam WORD
Number of reject cam.
dnDistanceRejectGate_p
DINT
Distance from reject gate to knife drum (curve zero of x axis) in increments (incr.).
Outputs
(Variable type: VAR_OUTPUT)
Name Data
type
Value/Meaning
Control of reject gate. The output is activated dependent upon the line speed, the
reject gate switching delay time and the distance from the reject gate to the knife
drum if the motion profile currently selected is the reject cam.
TRUE
Reject gate open
bOpenRejectGate BOOL
FALSE
Reject gate closed