2 multiplexeroutput function block, Multiplexeroutput function block -82, Cross cutter – Lenze EVS93xx CrossCutter User Manual
Page 250
Cross Cutter
Appendix
Prepared Solution Servo PLC / ECSxA 1.1 EN
6-82
6.6.2
MultiplexerOutput
function block
The MultiplexerOutput function block can be used to select a data interface to output status
information. The following data interfaces can be selected via the byOutputSource input byte:
Internal source in the form of status words (3 process data items: words 1 … 3)
CAN1 (4 process data items: words 0 … 3)
CAN2 (4 process data items: words 0 … 3)
CAN3 (4 process data items: words 0 … 3)
AIF1 (4 process data items: words 0 … 3)
AIF2 (4 process data items: words 0 … 3)
AIF3 (4 process data items: words 0 … 3)
Data words 2 and 3 are interpreted in bits and can be mapped to the input signals (bBit00 …
bBit31) as required using the internal multiplexer. An element of the internal index array
abyStatWord[0..31] is available for each of the output signals. This array is used to define, for
each bit in this status double word, the source (bBit00 … bBit31) from which the information for
this status double word has been taken (multiplexer).
Task information
Can be called in:
Cyclic task
Time-controlled task
(INTERVAL)
Event-controlled task
(EVENT)
Interrupt task