Variable
Value/Meaning
Name Data
type
Value/Meaning
ARRAY OF DINT
Variable for acceleration ramp for positioning when using variables
dnSetPositionTrimming_p and bLoadSetPositionTrimming. The ramp assumes
4000 rpm.
Possible settings
Default
Selection
xxx.L_CamPosCtrlLin1.adnTiPos[2]
1.000 s
0.010
{0.001 s}
130.000
ARRAY OF DINT
Variable for deceleration ramp for positioning when using variables
dnSetPositionTrimming_p and bLoadSetPositionTrimming. The ramp assumes
4000 rpm.
Possible settings
Default
Selection
xxx.L_CamPosCtrlLin1.adnTiPos[3]
1.000 s
0.010
{0.001 s}
130.000
ARRAY OF INT
Variable for forward motion (positive speed) for positioning when using variables
dnSetPositionTrimming_p and bLoadSetPositionTrimming.
Possible settings
Default
Selection
xxx.L_CamPosCtrlLin1.anSpeed[1]
200 rpm
-15000 {1
rpm} 15000
ARRAY OF INT
Variable for return motion (negative speed) for positioning when using variables
dnSetPositionTrimming_p and bLoadSetPositionTrimming.
Possible settings
Default
Selection
xxx.L_CamPosCtrlLin1.anSpeed[2]
200 rpm
-15000 {1
rpm} 15000
* xxx stands for the instance name of the block.
User-specific codes can be created starting at value C3000. 7 codes must be created for each
function block call.