Cross cutter, Appendix – Lenze EVS93xx CrossCutter User Manual
Page 171

Cross Cutter
Appendix
Prepared Solution Servo PLC / ECSxA 1.1 EN
6-3
Outputs
Global variables
(Variable type: VAR_GLOBAL)
Name Data
type
Value/Meaning
g_dnActRejectLength
DINT
Display indicating the reject length used to calculate the current motion profile
(g_wActCamRejectProfileNoCalc). The value is displayed in 0.0001[m_units].
g_dnActTestLength
DINT
Display indicating the test length used to calculate the current motion profile
(g_wActCamTestProfileNoCalc). The value is displayed in 0.0001[m_units].
g_dnActStartStopLength DINT
Display
indicating the start/stop length used to calculate the current motion profile
(g_wActCamStartStopProfileNoCalc). The value is displayed in 0.0001[m_units].
g_dnCuttingLengthLimit
DINT
Output indicating the maximum cutting length in 0.0001[m_units] possible when the
cross cutter is in continuous duty. Selecting a longer cutting length will lead to a
motion profile with a break in the asynchronous motion phase.
Note: The value of this output signal is only recalculated during a calculation
sequence (g_bCrossCutterCalcBusyCuttingProfile = TRUE).
g_dnRejectLengthLimit
DINT
Output indicating the maximum cutting length in 0.0001[m_units] possible when the
cross cutter is in continuous duty. Selecting a longer reject length will lead to a
motion profile with a break in the asynchronous motion phase.
Note: The value of this output signal is only recalculated during a calculation
sequence (g_bCrossCutterCalcBusyRejectProfile = TRUE).
g_dnTestLengthLimit
DINT
Output indicating the maximum cutting length in 0.0001[m_units] possible when the
cross cutter is in continuous duty. Selecting a longer test length will lead to a motion
profile with a break in the asynchronous motion phase.
Note: The value of this output signal is only recalculated during a calculation
sequence (g_bCrossCutterCalcBusyTestProfile = TRUE).
g_dnStartStopLengthLimit
DINT
Output indicating the maximum cutting length in 0.0001[m_units] possible when the
cross cutter is in continuous duty. Selecting a longer start/stop length will lead to a
motion profile with a break in the asynchronous motion phase.
Note: The value of this output signal is only recalculated during a calculation
sequence (g_bCrossCutterCalcBusyStartStopProfile = TRUE).
g_dnXAsynchronousCuttingLength
DINT
Output indicating the material length in 0.0001[m_units] to which the cross cutter is
set in the asynchronous motion phase. The value is the difference between the
cutting length and the synchronous X length.
Note: The value of this output signal is only recalculated during a calculation
sequence (g_bCrossCutterCalcBusyCuttingProfile = TRUE).
g_dnXAsynchronousRejectLength
DINT
Output indicating the material length in 0.0001[m_units] to which the cross cutter is
set in the asynchronous motion phase. The value is the difference between the
reject length and the synchronous X length.
Note: The value of this output signal is only recalculated during a calculation
sequence (g_bCrossCutterCalcBusyRejectProfile = TRUE).
g_dnXAsynchronousTestLength
DINT
Output indicating the material length in 0.0001[m_units] to which the cross cutter is
set in the asynchronous motion phase. The value is the difference between the test
length and the synchronous X length.
Note: The value of this output signal is only recalculated during a calculation
sequence (g_bCrossCutterCalcBusyTestProfile = TRUE).
g_dnXAsynchronousStartStopLength
DINT
Output indicating the material length in 0.0001[m_units] to which the cross cutter is
set in the asynchronous motion phase. The value is the difference between the
start/stop length and the synchronous X length.
Note: The value of this output signal is only recalculated during a calculation
sequence (g_bCrossCutterCalcBusyStartStopProfile = TRUE).