Cross cutter, Appendix – Lenze EVS93xx CrossCutter User Manual
Page 208

Cross Cutter
Appendix
Prepared Solution Servo PLC / ECSxA 1.1 EN
6-40
Possible settings:
Code
Default
Selection
Comment
C3361/
000
- -
{1[incr.]}
- Display code: Current master angle
C3365/
000
- -
{1[incr.]}
- Display code: Main integrator, current cam position
C3366/
000
- -
{1[incr.]}
- Display code: Auxiliary integrator, current tool position
C3367/
000
- -
{1[incr.]}
- Display code: Profile set position
C3369/
000
- -
{1[incr.]}
- Display code: Following error
Selection of application units
0 [mm]
C3501/
000
0 0
{1[m_units]}
1
1 [inch]
Display code: Status of state machine
100 "Init"
state
51 "LockToCamBusy"
state
50 "CamOperation"
state
40 "PositioningOperation"
state
30 "HomingOperation"
state
20 "ManualOperation"
state
10 "StandBy"
state
Switching over to other states is performed
from this initial state.
C3505/
000
- -
-
-
1 "Trouble"
state
C3620/
001
5.00 0.01…
{0.01[s]}
...129.99 Deceleration ramp for immediate stop
Assuming 4000 rpm
C3620/
002
5.00 0.01…
{0.01[s]}
...129.99 Acceleration ramp for positioning
Assuming 4000 rpm
C3620/
003
5.00 0.01…
{0.01[s]}
...129.99 Deceleration ramp for positioning
Assuming 4000 rpm
C3621/
001
200
0 ...
{1 rpm}
...15000 Speed for positioning in positive direction (CW)
C3621/
002
200
0 ...
{1 rpm}
...15000 Speed for positioning in negative direction (CCW)
C3622/
001
5.000 0.000...
{0.0001[s]}
...129.99
Deceleration ramp for immediate stop for manual jog
Assuming 4000 rpm
C3622/
002
5.000 0.000...
{0.0001[s]}
...129.99
Acceleration and deceleration ramp for normal operation;
Assuming 4000 rpm
C3622/
003
5.000 0.000...
{0.0001[s]}
...129.99
Acceleration and deceleration ramp for manual jog
Assuming 4000 rpm
C3623/
001
200 0
...
{1 rpm}
...15000
Speed for manual jog in positive direction (CW)
C3623/
002
200 0
...
{1 rpm}
...15000
Speed for manual jog in negative direction (CCW)
C3624
/001
5.00 0.01…
{0.01[s]}
...129.99 Deceleration ramp for immediate stop (function abort) for homing
Assuming 4000 rpm
C3624
/002
5.00 0.01…
{0.01[s]}
...129.99 Acceleration ramp for homing
Assuming 4000 rpm
C3624
/003
5.00 0.01…
{0.01[s]}
...129.99 Deceleration ramp for homing
Assuming 4000 rpm
C3625
/001
200
0 ...
{1 rpm}
...15000 Speed for homing in positive direction (CW)
C3625
/002
200
0 ...
{1 rpm}
...15000 Speed for homing in negative direction (CCW)
C3626
/000
0 0
{0.0001
[s_units]}
214000.0000 Entry indicating the position of the homing switch
C3627
/000
0 0
{0.0001
[s_units]}
214000.0000 Target position of tool following homing
C3628/
000
0.0000 0
{0.0001
[s_units]}
360.0000 Target position of positioning