Cross cutter, Appendix – Lenze EVS93xx CrossCutter User Manual
Page 245

Cross Cutter
Appendix
Prepared Solution Servo PLC / ECSxA 1.1 EN
6-77
The individual status words are output to system variables (designated Word 0, Word 1, Word 2
and Word 4) dependent on the operating mode in C4000/000:
Signal source
Word 0
Word 1
Word 2
Word 3
C4000/000 = 0
C0135/000
C4152/000
C4150/000
C4000/000 = 1
CAN1_wDctrlStat CAN1_nOutW1_a CAN1_nOutW2_a CAN1_nOutW3_a
C4000/000 = 2
CAN2_nOutW1_a CAN2_nOutW2_a CAN2_nOutW3_a CAN2_nOutW4_a
C4000/000 = 3
CAN3_nOutW1_a CAN3_nOutW2_a CAN3_nOutW3_a CAN3_nOutW4_a
C4000/000 = 4
AIF1_wDctrlStat AIF1_nOutW1_a AIF1_nOutW2_a AIF1_nOutW3_a
C4000/000 = 5
AIF2_nOutW1_a AIF2_nOutW2_a AIF2_nOutW3_a AIF2_nOutW4_a
C4000/000 = 6
AIF3_nOutW1_a AIF3_nOutW2_a AIF3_nOutW3_a AIF3_nOutW4_a
The illustration on the previous page shows the factory-set default configuration of the 32-bit
application status word. Users can also adapt the configuration of the application status word in
accordance with their individual needs by setting the values of codes C4012/001 to C4012/032
accordingly.
An example of how the GDC parameterisation software can be used to reconfigure the
application status word bit by bit appears below:
You will find the code in the complete code list or in the menu Short Setup Control/Status Interface
Status Interface:
Select the application status word bit you wish to reconfigure.
Example: To assign bit 6 of the application status word, select code C4012/007:
Start
Step 1