18 varvertshaftextposition, 19 varvertshaftextvelocity, Varvertshaftextposition -34 – Lenze EVS93xx CrossCutter User Manual
Page 202: Varvertshaftextvelocity -34, Cross cutter, Appendix

Cross Cutter
Appendix
Prepared Solution Servo PLC / ECSxA 1.1 EN
6-34
6.1.18 VarVertShaftExtPosition
Inputs
Global variables
(Variable type: VAR_GLOBAL)
Name Data
type
Value/Meaning
Enable external master signal.
TRUE
X axis defined externally.
g_bVertShaftExtEnable BOOL
FALSE
X axis generated by virtual master.
Positioning to external master angle
TRUE
Positioning to external master angle.
g_bPosToVertShaftExt BOOL
FALSE
Direct switch to external master angle.
6.1.19 VarVertShaftExtVelocity
Inputs
Global variables
(Variable type: VAR_GLOBAL)
Name Data
type
Value/Meaning
Selection of external master signal
TRUE Digital
frequency
via digital frequency
input DFIN.
g_bTypeOfVertShaftExt BOOL
FALSE
Master angle via system bus (CAN).
Selection of operating mode
0 Continuous
operation
The external digital frequency entry is
integrated continuously.
g_byVertShaftExtVelMode BYTE
1 Start/stop
operation
The external digital frequency entry is
only integrated when a corresponding
start/stop signal is pending at
g_bStartStopVertShaftExtVel.
Start/stop signal for "Start/stop operation"
TRUE Start
integration.
Integration will continue at least until the
next zero crossing.
g_bStartStopVertShaftExtVel BOOL
FALSE No
integration/abort previously activated
integration on the next zero crossing.
g_nVertShaftExt_v INT
Entry indicating the external digital frequency/speed in [incr./ms]
Invert external digital frequency entry.
g_bVertShaftExtVelCwCcw BOOL
TRUE
g_nVertShaftExt_v inverted internally.