8 varcrosscuttertrouble, Varcrosscuttertrouble -21, Cross cutter – Lenze EVS93xx CrossCutter User Manual
Page 189: Appendix

Cross Cutter
Appendix
Prepared Solution Servo PLC / ECSxA 1.1 EN
6-21
Outputs
Global variables
(Variable type: VAR_GLOBAL)
Name Data
type
Value/Meaning
This output indicates the enabling of print-mark synchronisation by the system.
TRUE
Print-mark synchronisation can be used.
g_bSystemReadyToUseTP BOOL
FALSE
Print-mark synchronisation cannot be used.
6.1.8 VarCrossCutterTrouble
Inputs
Global variables
(Variable type: VAR_GLOBAL)
Name Data
type
Value/Meaning
User error triggered externally
TRUE
An external user error has been
triggered.
g_bExtUserError BOOL
FALSE No
errors.
Outputs
Global variables
(Variable type: VAR_GLOBAL)
Name Data
type
Value/Meaning
Status signal: A motion profile currently being used by the application has been
calculated.
TRUE
A motion profile currently being used by
the application has been calculated.
g_bWrongSetCamProfileNoForCalc BOOL
FALSE
The calculated motion profile is not
currently being used by the application.
Status signal: An error occurred whilst calculating the motion profile for the new
cutting length.
TRUE
An error has occurred during calculation.
g_bErrorCrossCutterCuttingProfileCalc
Block
BOOL
FALSE
Calculation completed without errors.
Status signal: An error occurred whilst calculating the motion profile for the new
reject length.
TRUE
An error has occurred during calculation.
g_bErrorCrossCutterRejectProfileCalc
Block
BOOL
FALSE
Calculation completed without errors.
Status signal: An error occurred whilst calculating the motion profile for the new test
length.
TRUE
An error has occurred during calculation.
g_bErrorCrossCutterTestProfileCalc
Block
BOOL
FALSE
Calculation completed without errors.
Status signal: An error occurred whilst calculating the motion profile for the new
start/stop length.
TRUE
An error has occurred during calculation.
g_bErrorCrossCutterStartStopProfile
CalcBlock
BOOL
FALSE
Calculation completed without errors.