beautypg.com

Show temperatures, Show temperatures -7, Command mode – Avaya Cajun P550R User Manual

Page 618: Description, Syntax, Sample output, Systems

background image

Command Reference Guide for the Avaya P550R, P580, P880, and P882 Multiservice Switches, v5.3.1

30-7

Temperatures

show temperatures

Command Mode

User

Description

Displays the current temperatures and the configured temperature
limits. There is no reverse mapping to this command.

Syntax

Table 30-6. Default Shutdown and Warning Temperatures

Sample Output

The following example displays the current switch temperatures.

>show temperature
Slot 1 Sensor Backplane Sensor

CPU Sensor
Shutdown Temperature

50

50 100
Upper Warning Temperature

45

45 85
Current Temperature

29

35 68
Lower Warning Temperature

5

5 5
Low Limit Temperature

0

0 0

Systems

Avaya Multiservice Switches

To View:

show temperatures

Shutdown &
Warning
Temperatures

Shutdown

Upper

Lower
Warning

Low Limit

CPU Sensor

100°

85°

All others

65°