Temperatures
show temperatures
Command Mode
User
Description
Displays the current temperatures and the configured temperature
limits. There is no reverse mapping to this command.
Syntax
Table 30-6. Default Shutdown and Warning Temperatures
Sample Output
The following example displays the current switch temperatures.
>show temperature
Slot 1 Sensor Backplane Sensor
CPU Sensor
Shutdown Temperature
50
50 100
Upper Warning Temperature
45
45 85
Current Temperature
29
35 68
Lower Warning Temperature
5
5 5
Low Limit Temperature
0
0 0
Systems
Avaya Multiservice Switches
To View:
show temperatures
Shutdown &
Warning
Temperatures
Shutdown
Upper
Lower
Warning
Low Limit
CPU Sensor
100°
85°
5°
0°
All others
65°
60°
5°