Set temperature (shutdown), Set temperature (shutdown) -3, Command mode – Avaya Cajun P550R User Manual
Page 614: Description, Syntax
Command Reference Guide for the Avaya P550R, P580, P880, and P882 Multiservice Switches, v5.3.1
30-3
Temperatures
set temperature (shutdown)
Command Mode
Configuration
Description
Sets the shutdown temperature for a specific component of the
Cajun switch. The default values are listed in Table 30-2.
Table 30-2. Default Shutdown and Warning Temperatures
Syntax
Table 30-3 lists the parameters, keywords, and arguments.
Table 30-3. Parameters, Keywords, Arguments
Shutdown &
Warning
Temperatures
Shutdown
Upper
Lower
Warning
Low Limit
CPU Sensor
100°
85°
5°
0°
All others
65°
60°
5°
0°
To Enable:
set temperature {supervisor-slot | backplane-sensor | cpu-sensor |
probe} shutdown
Name
Definition
supervisor-slot |
backplane-sensor |
cpu-sensor | probe
These parameters indicate which component of the switch is of
interest.
Note:
After you change the temperature settings for the active
supervisor, you must synchronize the active and standby
supervisors to copy the temperature settings to the
standby supervisor.
shutdown
Shutdown is a required parameter and indicates that the
shutdown limit temperature is being set.
temperature
Temperature is a required parameter and when the switch
measures this value on this component, it shuts itself down in
order to prevent either inconsistent behavior or damage to itself
or surrounding equipment. The command checks the entered
temperature value and ensures that the temperature being set is
not above 127, and not below -128 degrees, the backplane sensor
and supervisor are not below 60 and not above 127 degrees, and
the CPU sensor is not below 85 and not above 127 degrees.