clock summer-time recurring
Command Mode
Enable
Description
Allows you to configure the system to automatically switch to
summer time hours (U.S. Daylight Savings Time). The command
format allows for an annual configuration and a one-time change
for a particular year. To disable automatic summer time use the "no"
form of this command. If parameters are excluded for recurring
summer time hours, then summer time is set to default.
Syntax
Table 2-6. Parameters, Keywords, Arguments
Sample Output
The following command sets the recurring summer time hours from
the first week of April on Sunday at 2:00 a.m. to the second week in
January on Monday at 2:00 a.m.
># clock summer-time recurring 1 Sunday Apr 02:00 2 Mon
Jan 02:00
Set of recurring summer time hours succeeded
Systems
Avaya P550R/P580/P880/P882 Multiservice Switches.
To Enable:
clock summer-time recurring [
To
Disable:
[no] clock summer-time
Name
Definition
week
Week of the month ( 1 to 5 (where 5=last) ).
day
Day of the week (for example: Sunday, Monday).
month
Month (for example: January, February).
date
Date of the month (1 to 31).
hh:mm
Time (military format) in hours and minutes.
offset
The number of minutes to add during summer time
(default 60). (Optional)