Set temperature (warning), Set temperature (warning) -5, Command mode – Avaya Cajun P550R User Manual
Page 616: Description, Syntax
Command Reference Guide for the Avaya P550R, P580, P880, and P882 Multiservice Switches, v5.3.1
30-5
Temperatures
set temperature (warning)
Command Mode
Configuration
Description
Sets the warning temperature (in Celsius) for a specific component
of the switch. The default values are listed in Table 30-4.
Table 30-4. Default Shutdown and Warning Temperatures
Syntax
Table 30-5. Parameters, Keywords, Arguments
Shutdown &
Warning
Temperatures
Shutdown
Upper
Lower
Warning
Low Limit
CPU Sensor
100°
85°
5°
0°
All others
65°
60°
5°
0°
To Enable:
set temperature {supervisor-slot | backplane-sensor | cpu-sensor |
probe} warning {upper | lower | low-limit}
Name
Definition
supervisor-slot | backplane-
sensor | cpu-sensor | probe
Indicates which component of the switch is of interest.
Note:
After you change the temperature settings for the active
supervisor, you must synchronize the active and standby
supervisors to copy the temperature settings to the standby
supervisor.
warning
Required parameter indicating that a warning limit is being
modified.