Command Reference Guide for the Avaya P550R, P580, P880, and P882 Multiservice Switches, v5.3.1
24-9
RADIUS
set radius authentication switch-service-type-
required
Command Mode
Configure
Description
If you enable switch-service-type-required, the switch will only
honor Access Accept messages with the vendor specific attrib of
“Cajun-Service-Type”. This is to prevent users with RADIUS
accounts who have administrative privileges on other devices from
login in to the switch with administrative privileges. You would give
users who need to manage the switch access by adding the “Cajun-
Service-Type” to the user login in the “client file” on the RADIUS
server.
Syntax
Sample Output
The following command would enable the switch-service-type-
required setting:
switch-service-type-required enabled
Systems
P550R/P580/P880/P882
To set
RADIUS
switch
service type
required to
enabled
set radius authentication switch-service-type-required enabled
To set
RADIUS
switch
service type
required to
disabled