Show cpu_redundancy, Show cpu_redundancy -51, Command mode – Avaya Cajun P550R User Manual
Page 606: Description, Sample output, Systems
Command Reference Guide for the Avaya P550R, P580, P880, and P882 Multiservice Switches, v5.3.1
29-51
System
show cpu_redundancy
Command Mode
User
Description
Displays configuration and status information about the redundant
supervisor.
Sample Output
The following example displays the config information for the
redundant supervisor slots 1 and 2.
> show cpu_redundancy status
Status Information
Slot1 CPU
Slot2 CPU
------------------
---------
---------
Status
Active
N/A
BOOT Version
v5.00.1
N/A
Power-Up/Reset Image
N/A
N/A
APP1 Version
b5.00.14
N/A
APP1 Checksum
0x4be7
N/A
APP2 Version
x5.00.95
N/A
APP2 Checksum
0x8cc2
N/A
Startup Config Date/Time Modified 00-Dec-06 09:35:25 N/A
Startup Config Checksum
0x41dc
N/A
Statistic Information
---------------------
Health Reports Sent 0
Health Reports Received 0
Health Reports Timeouts 0
Health Reports Missed 0
Synchronization Status
----------------------
No status available.
139(configure)#
Systems
Avaya P550R/P580/P880/P882 Multiservice Switches
To Enable:
show cpu_redundancy
Table 29-30. Parameters, Keywords, Arguments
Name
Definition
config
Displays Configuration information for the redundant
supervisor slots 1 and 2.
status
Displays Status information for the redundant
supervisor slots 1 and 2.