Chapter 19: SNMPv3 Protocol
Section III: SNMPv3 Operations
214
5. To create an SNMPv3 Notify Table entry, click Add.
The Add New SNMPv3 Notify Page is shown in Figure 72.
Figure 72 Add New SNMPv3 Notify Page
6. In the Notify Name field, enter the name associated with this trap
message.
Enter a descriptive name of up to 32 alphanumeric characters. For
example, you might want to define a trap message for hardware
engineering and enter a value of “hardwareengineeringtrap” for
the Notify Name.
7. In the Notify Tag field, enter a description name of the Notify Tag.
Enter a name of up to 32 alphanumeric characters.
8. In the Notify Type field, enter one of the following message types:
Trap
Indicates this notify table is used to send traps. With this message
type, the switch does not expects a response from the host.
Inform
Indicates this notify table is used to send inform messages. With
this message type, the switch expects a response from the host.
9. In the Storage Type field, select one of the following storage types for
this table entry:
Volatile
Select this storage type if you do not want the ability to save an
entry in the Notify Table to the configuration file. After making
changes to a Notify Table entry with a Volatile storage type, the
Save Config menu selection does not appear.