The top portion of the page displays the PoE operating status of
the selected ports. The columns are defined here:

Port
Port number.

PoE Function
Whether PoE is enabled or disabled on the port. The default
setting is enabled.

Power Consumed
The amount of power in milliwatts currently consumed by the
powered device connected to the port. If the port is not
connected to a powered device, this value will be 0 (zero).

Power Limit
The maximum amount of power allowed by the port for the
device. The default is 15,400 milliwatts (15.4 W).

Power Priority
The port priority. This can be Critical, High, or Low. The default is
Low.

Power Class
The IEEE 802.3af class of the device.

Voltage
The voltage being delivered to the powered device

Current
The current drawn by the powered device.

Power Status
Whether power is being supplied to the device. Status will be one
of the following:

ON: Power is being supplied to a powered device.

OFF - Disabled by user: PoE is disabled on the port.

Off - Detection in process: PoE is enabled on the port, but either
no device is connected to the port or the device is not a powered
device.

6. To enable or disable PoE on a port, set PoE Function to either Enable

or Disable. The default is enabled.

7. To change a port’s priority, set Power Priority to Critical, High, or

Low. A port can belong to only one priority level at a time. The default
is Low.