Read:interval:pkavg, Read:marker:average, Read:marker:delta – Boonton 4500B Peak Power Meter User Manual
Page 262: Read:marker:maximum, Read:interval:pkavg? -62, Read:marker:average? -62, Read:marker:delta? -62, Read:marker:maximum? -62, Boonton 4500b rf peak power analyzer, Remote operation
![background image](/manuals/401804/262/background.png)
Boonton 4500B RF Peak Power Analyzer
Remote Operation
5-62
READ:INTERval:PKAVG?
Description:
For the specified channel, return the peak-to-average ratio of the power or voltage between marker
1 and marker 2. The units are dB for logarithmic channel units or percent for linear channel units.
Syntax:
READ[1|2|6|7]:INTERval:PKAVG?
Returns:
CC, peak-to-average ratio of power or voltage between markers
Where CC is the measurement condition code.
Valid Modes:
Pulse and Modulated
READ:MARKer:AVERage?
Description:
For the specified channel and marker, return the average power or voltage at the marker. The
units are the same as the specified channel.
Syntax:
READ[1|2|3|4|5|6|7]:MARKer[1|2]:AVERage?
Returns:
CC, average power or voltage at marker
Where CC is the measurement condition code.
Valid Modes:
Pulse and Modulated.
READ:MARKer:DELTa?
Description:
For the specified channel return the difference between MK1 and MK2. The units will be the same
as marker units.
Syntax:
READ[1|2|3|4|5|6|7]:MARKer:DELTa?
Returns:
CC, (MK1 – MK2)
Where CC is the measurement condition code.
Valid Modes:
All
READ:MARKer:MAXimum?
Description:
For the specified channel and marker, return the maximum power or voltage at the marker. The
units are the same as the specified channel.
Syntax:
READ[1|2|3|4|6|7]:MARKer[1|2]:MAXimum?
Returns:
CC, maximum power or voltage at marker
Where CC is the measurement condition code.
Valid Modes:
Pulse and Modulated.