beautypg.com

Display:parameter:mode, Display:channel:bottom:left, Display:channel:bottom:middle – Boonton 4500B Peak Power Meter User Manual

Page 221: Display:channel:bottom:right, Display:parameter:mode -21, Display:channel:bottom:left -21, Display:channel:bottom:middle -21, Display:channel:bottom:right -21, Boonton 4500b rf peak power analyzer, Remote operation

background image

Boonton 4500B RF Peak Power Analyzer

Remote Operation

5-21

DISPlay:PARAmeter:MODE

Description:

Set or return the type of content displayed in the parameter area above the trace box. The STAT
(status) command causes a fixed set of nine status parameters for the active channel to be
displayed. The MEAS command causes a group of nine user selected auto-measure and fixed
parameters from any measurement channel to be displayed.

Syntax:

DISPlay:PARAmeter:MODE

Argument:

= {MEAS, STAT}

Valid Modes:

Pulse Mode only. Note: Modulated mode does not display Status and Measurement parameters.
Statistical mode displays a fixed combination of status and auto-measure parameters.

DISPlay:CHANnel:BOTtom:LEFT

Description:

Set or return the channel for the auto-measure or fixed parameter displayed in the Bottom row,
Left

column

of

the

nine

element

parameter

field

above

the

trace

box.

DISPlay:PARAmeter:MODE must be set to MEAS.

Syntax:

DISPlay:CHANnel:BOTtom:LEFT

Argument:

= {CH1, CH2, TRIG1, TRIG2, CHM, MEM1, MEM2}

Valid Modes:

Pulse Mode only. Note: Modulated mode does not display Status and Measurement parameters.
Statistical mode displays a fixed combination of status and auto-measure parameters.

DISPlay:CHANnel:BOTtom:MIDdle

Description:

Set or return the channel for the auto-measure or fixed parameter displayed in the Bottom row,
Middle

column

of

the

nine

element

parameter

field

above

the

trace

box.

DISPlay:PARAmeter:MODE must be set to MEAS.

Syntax:

DISPlay:CHANnel:BOTtom: MIDdle

Argument:

= {CH1, CH2, TRIG1, TRIG2, CHM, MEM1, MEM2}

Valid Modes:

Pulse Mode only. Note: Modulated mode does not display Status and Measurement parameters.
Statistical mode displays a fixed combination of status and auto-measure parameters.


DISPlay:CHANnel:BOTtom:RIGHt

Description:

Set or return the channel for the auto-measure or fixed parameter displayed in the Bottom row,
Right

column

of

the

nine

element

parameter

field

above

the

trace

box.

DISPlay:PARAmeter:MODE must be set to MEAS.

Syntax:

DISPlay:CHANnel:BOTtom: RIGHt

Argument:

= {CH1, CH2, TRIG1, TRIG2, CHM, MEM1, MEM2}

Valid Modes:

Pulse Mode only. Note: Modulated mode does not display Status and Measurement parameters.
Statistical mode displays a fixed combination of status and auto-measure parameters.