![background image](/manuals/401804/221/background.png)
Boonton 4500B RF Peak Power Analyzer
Remote Operation
5-21
DISPlay:PARAmeter:MODE
Description:
Set or return the type of content displayed in the parameter area above the trace box. The STAT
(status) command causes a fixed set of nine status parameters for the active channel to be
displayed. The MEAS command causes a group of nine user selected auto-measure and fixed
parameters from any measurement channel to be displayed.
Syntax:
DISPlay:PARAmeter:MODE
Argument:
Valid Modes:
Pulse Mode only. Note: Modulated mode does not display Status and Measurement parameters.
Statistical mode displays a fixed combination of status and auto-measure parameters.
DISPlay:CHANnel:BOTtom:LEFT
Description:
Set or return the channel for the auto-measure or fixed parameter displayed in the Bottom row,
Left
column
of
the
nine
element
parameter
field
above
the
trace
box.
DISPlay:PARAmeter:MODE must be set to MEAS.
Syntax:
DISPlay:CHANnel:BOTtom:LEFT
Argument:
Valid Modes:
Pulse Mode only. Note: Modulated mode does not display Status and Measurement parameters.
Statistical mode displays a fixed combination of status and auto-measure parameters.
DISPlay:CHANnel:BOTtom:MIDdle
Description:
Set or return the channel for the auto-measure or fixed parameter displayed in the Bottom row,
Middle
column
of
the
nine
element
parameter
field
above
the
trace
box.
DISPlay:PARAmeter:MODE must be set to MEAS.
Syntax:
DISPlay:CHANnel:BOTtom: MIDdle
Argument:
Valid Modes:
Pulse Mode only. Note: Modulated mode does not display Status and Measurement parameters.
Statistical mode displays a fixed combination of status and auto-measure parameters.
DISPlay:CHANnel:BOTtom:RIGHt
Description:
Set or return the channel for the auto-measure or fixed parameter displayed in the Bottom row,
Right
column
of
the
nine
element
parameter
field
above
the
trace
box.
DISPlay:PARAmeter:MODE must be set to MEAS.
Syntax:
DISPlay:CHANnel:BOTtom: RIGHt
Argument:
Valid Modes:
Pulse Mode only. Note: Modulated mode does not display Status and Measurement parameters.
Statistical mode displays a fixed combination of status and auto-measure parameters.