5-17
5.5.4 DISPlay Subsystem
The DISPlay group of commands is used to control the selection and presentation of textual, graphical and TRACe
measurements.
DISPlay:ACTive
Description:
Set or return the active channel. The active channel trace is drawn on top of all other traces. The
active channel‘s menu appears on the right side of the display, and its status display appears above
the trace area if status display is selected.
Syntax:
DISPlay:ACTive
Argument:
Valid Modes:
All
DISPlay:BACKlight:BRIGhtness
Description:
Set or return the backlight brightness for the LCD display in percent.
Syntax:
DISPlay:BACKlight:BRIGhtness
Argument:
Valid Modes:
All
DISPlay:BRIGhtness:COLor
Description:
Set or return the color item to be set by the RGB commands that follow.
Syntax:
DISPlay:BRIGhtness COLor
Argument:
Color Item Table {
BACKGROUND
GRID
TIME_MARKERS
CH1
CH2
TRIG1
TRIG2
CH_MATH
MEM1
MEM2
REF_LINES
STATUS_MSG
ERROR_MSG
PATH_MSG
PRIORITY_MSG
BOX_LOW
BOX_HIGH
LABEL_BACK
MENU_LABEL
DATA_BACK MENU_DATA
DATA_LOW
TEXT}
Valid Modes:
All