Display:channel:top: middle, Display:channel:top: right, Display:parameter:bottom:left – Boonton 4500B Peak Power Meter User Manual
Page 223: Display:parameter:bottom:middle, Display:channel:top: middle -23, Display:channel:top: right -23, Display:parameter:bottom:left -23, Display:parameter:bottom:middle -23, Boonton 4500b rf peak power analyzer, Remote operation
Boonton 4500B RF Peak Power Analyzer
Remote Operation
5-23
DISPlay:CHANnel:TOP: MIDdle
Description:
Set or return the channel for the auto-measure or fixed parameter displayed in the Top row,
Middle
column
of
the
nine
element
parameter
field
above
the
trace
box.
DISPlay:PARAmeter:MODE must be set to MEAS.
Syntax:
DISPlay:CHANnel:TOP: MIDdle
Argument:
Valid Modes:
Pulse Mode only. Note: Modulated mode does not display Status and Measurement parameters.
Statistical mode displays a fixed combination of status and auto-measure parameters.
DISPlay:CHANnel:TOP: RIGHt
Description:
Set or return the channel for the auto-measure or fixed parameter displayed in the Top row, Right
column of the nine element parameter field above the trace box. DISPlay:PARAmeter:MODE
must be set to MEAS.
Syntax:
DISPlay:CHANnel:TOP: RIGHt
Argument:
Valid Modes:
Pulse Mode only. Note: Modulated mode does not display Status and Measurement parameters.
Statistical mode displays a fixed combination of status and auto-measure parameters.
DISPlay:PARAmeter:BOTtom:LEFT
Description:
Set or return the auto-measure or fixed parameter displayed in the Bottom row, Left column of the
nine element parameter field above the trace box. The selected parameter will be for the currently
active channel. See DISPlay:ACTive command. DISPlay:PARAmeter:MODE must be set to
MEAS.
Syntax:
DISPlay:PARAmeter:BOTtom:LEFT
Argument:
See Display Parameter Table below
Valid Modes:
Pulse Mode only. Note: Modulated mode does not display Status and Measurement parameters.
Statistical mode displays a fixed combination of status and auto-measure parameters.
DISPlay:PARAmeter:BOTtom:MIDdle
Description:
Set or return the auto-measure or fixed parameter displayed in the Bottom row, Middle column of
the nine element parameter field above the trace box. The selected parameter will be for the
currently active channel. See DISPlay:ACTive command. DISPlay:PARAmeter:MODE must be
set to MEAS.
Syntax:
DISPlay:PARAmeter:BOTtom:MIDdle
Argument:
See Display Parameter Table below
Valid Modes:
Pulse Mode only. Note: Modulated mode does not display Status and Measurement parameters.
Statistical mode displays a fixed combination of status and auto-measure parameters.