a.
List the saved configuration files:
> FUP INFO $SYSTEM.ZSYSCONF.CONF*
b.
Run SCF
> SCF
2.
Save the current configuration:
-> SAVE CONFIGURATION xx.yy
Define xx and yy as you like. One option is for xx to reflect a major configuration change
and yy to reflect a minor configuration change.
This message appears:
The configuration file $SYSTEM.ZSYSCONF.CONFxxyy has been created.
If you specify an existing configuration file, SCF asks if you want to replace it. If you do not
want to replace it, you must repeat the Save procedure with a new file name.
3.
Exit SCF.
Receiving Software Into the Archive
The act of receiving software packages into the archive involves copying the software packages
from their tape or disk subvolumes into the archive on the host system. These software packages
can then be used to update the software configuration of your system.
A planner performs these steps to receive the product files into the software archive on the host
system. Repeat these steps for all the software packages being received. Packages received remain
in the archive until they are explicitly deleted or backed up; see
(Package) through ZPHIHMI” (page 160)
and
“Deleting a Software Input (Package) through ZPHIHMI”
.
To receive software into the archive:
1.
Launch the NonStop Software Essentials interface, as described in
Software Essentials Interface” (page 26)
, logging on as Planner with permission to receive
software.
2.
Navigate to the Receive Software Request page, which can be launched in any of the following
ways:
•
From the Receive Software link on the Work Panel of the NonStop Software Essentials
Home page.
•
From the Receive Software button on the
•
From the Requests menu on the menu bar of any NonStop Software Essentials page by
selecting Software Installation > Receive Software.
3.
Specify the details for the receive request using the Receive Software Request page. The page
consists of these three tabs, in which the details are specified:
•
•
•
Make any desired changes to the fields in all three tabs before clicking the Submit button
located beneath the tabs. Default values will be used for any fields not specified by the user,
so it is possible to proceed to step 4 and click Submit without making any changes. In that
case, you would initiate a receive software operation from the default tape drive using all
default settings.
•
The Main tab is used to assign and gather initial information about the request.
Receiving Software Into the Archive