If you are installing a SUT or other software that required system generation, load the new
operating system. If you made any changes to the CONFTEXT file, DSM/SCM has run system
generation and you must perform system load even if the software you are installing does not
require it.
NOTE:
If you used an OVERRIDE-SYSNN parameter (see
OVERRIDE-SYSNN-DIFFERENT-OS” (page 246)
), you do not need to perform a system load.
8.
RUN INSTALL^TEMPLATES to update EMS template files.
EMS templates format EMS messages. The Run INSTALL^TEMPLATE instruction is generated
only on the basis of product files present in the software configuration. If you change the
software configuration to include products that force system generation, DSM/SCM directs a
system generation program to run TEMPLI, ensuring installation of the user template specified
in the CONFTEXT file.
NOTE:
DSM/SCM decides whether a system generation program should run TEMPLI based
on the product files in the software configuration on which Build/Apply is performed. If you
add the user template to the CONFTEXT file but keep the same configuration, DSM/SCM
does not run TEMPLI through system generation or generate the operator instruction Run
INSTALL^TEMPLATE. As a result, the user template is not installed.
To run the INSTALL^TEMPLATES program to install the EMS templates in their proper locations:
a.
Set the volume and subvolume to $SYSTEM.ZINSAIDS.
b.
Load the TACLMACS file.
c.
Enter the command INSTALL^TEMPLATES.
9.
DOWN/STOP any DEVICE/LINE using filename.
Use SCF to STOP these DEVICES/LINES, and then to start them
again.
product number product name includes IOP OBJECT code changes.
If one or more input/output processes (IOP) files change in this configuration revision but does
not require system generation and one or more (IOPs) have changed, use SCF to:
a.
Stop all devices and lines that use the IOP file.
b.
Restart the devices and lines to put the new IOP file into effect. For more information,
refer to the SCF Reference Manual for G-Series RVUs or SCF Reference Manual for J and
H-Series RVU.
10.
Restart all applications.
Use the TI to complete any necessary DSM/SCM activities.
The last step in activating the new software is to restart all the applications you stopped in
Step 1.
122