beautypg.com

Power:t1, Power:t2 – GW Instek PEL-3000 Series Programming Manual User Manual

Page 97

background image

COMMNAND OVERVIEW

95

:POWer:T1

Set

Query

Description

Sets the T1 timer settings for the CP dynamic
mode.

Syntax

:POWer:T1 {[s] | MINimum | MAXimum}

Query Syntax

:POWer:T1?

Related
Commands

:POWer:T2

Parameter

[s]

T1 timer setting in
seconds

MINIMUM or MIN

Minimum time

MAXIMUM or MAX

Maximum time

Return parameter

Returns the T1 timer time
in s.

Example

:POWer:T1 0.200
Sets the T1 timer time to 200ms.

Query example

:POWer:T1?
>0.200
Returns the T1 timer time as 200ms.

:POWer:T2

Set

Query

Description

Sets the T2 timer settings for the CP dynamic
mode.

Syntax

:POWer:T2 {[s]| MINimum | MAXimum}

Query Syntax

:POWer:T2?

Related
Commands

:POWer:T1

Parameter

[s]

T2 timer setting in
seconds

MINIMUM or MIN

Minimum time

MAXIMUM or MAX

Maximum time

Return parameter

Returns the T2 timer time
in ms.