beautypg.com

Configure]:step:crl, Configure]:step:cr – GW Instek PEL-3000 Series Programming Manual User Manual

Page 62

background image

PEL-3000 Programming Manual

60

[:CONFigure]:STEP:CRL

Set

Query

Description

Configures the step resolution for CR Low Range.
Note: The step resolution setting will be
automatically rounded to the closest multiple of
the base resolution.

Syntax

[:CONFigure]:STEP:CRL {[ MHO ] | MINimum |
MAXimum }

Query Syntax

[:CONFigure]:STEP:CRL?

Parameter

[ MHO ]

Step resolution. (MHO)

MINIMUM or MIN

Minimum step resolution

MAXIMUM or MAX

Maximum step resolution

Return parameter

Returns the range and the
step resolution.

Example

:STEP:CRL 0.008
Sets the step resolution to 0.008℧.

Query example

:STEP:CRL?
>CRL:0.008
Returns the step resolution (0.008℧).

[:CONFigure]:STEP:CR

Set

Query

Description

Returns the step resolution for each CR Mode
range as a string.

Query Syntax

[:CONFigure]:STEP:CR?

Return parameter

Returns the CRH, CRM
and CRL step resolution
settings (in MHO).

Query example

:STEP:CR?
> CRH:0.8, CRM:0.08, CRL:0.008
Returns the CR mode step resolution for each range.