COMMNAND OVERVIEW

103

Syntax

:PROGram:RUN{SKIP|AUTO|MANual}

Query Syntax

:PROGram:RUN? { Run:Skip|Automatic|Manual}

Parameter

SKIP

Sets the run state to skip

AUTO

Sets the run state to automatic

MANual

Sets the run state to manual

Return Parameter Run:Skip

Run state = Skip

Run:Automatic Run state = Automatic

Run:Manual

Run state = Manual

Example

:PROGram:RUN SKIP
Skips the selected step.

Query example

:PROGram:RUN?
>Run:Skip
Returns the “Run” state (skip).

:PROGram:ONTime

Set

Query

Description

Sets or queries the On-Time for the selected step
number. Resolution 0.1 seconds.

Syntax

:PROGram:ONTime {[s]}

Query Syntax

:PROGram:ONTime?

Parameter

[s]

(0.1~60) On-Time in
seconds

Turns the On-Time off.

Return Parameter

On-Time:

Example

:PROGram:ONTime 1
Sets the On-Time to 1 second.

Query example

:PROGram:ONTime?
>On-Time:1.0
Returns the On-Time (1 second).

:PROGram:OFFTime

Set

Query

Description

Sets or queries the Off-Time for the selected step
number.