COMMNAND OVERVIEW

141

:STATus:PRESet

Set

Description

The :STATus:PRESet command resets the enable
registers NTR/PTR registers from Operation
Status, Questionable Status and CSummary Status
registers.

Preset Value

Register

Preset

Operation Status Enable

All bits set to 1

Operation Status PTR

All bits set to 1

Operation Status NTR

All bits set to 0

Questionable Status Enable

All bits set to 0

Questionable Status PTR

All bits set to 1

Questionable Status NTR

All bits set to 0

CSummary Status Enable

All bits set to 0

CSummary Status PTR

All bits set to 1

CSummary Status NTR

All bits set to 0

Syntax

:STATus:PRESet

:STATus:QUEStionable:CONDition?

Set

Query

Description

Returns the status of the Questionable Status
Condition register. See page 154 for details.

Query Syntax

:STATus:QUEStionable:CONDition?

Return parameter Condition

Condition

1

OV

512

UV

2

OC

1024

EXT

8

OP

2048

REV

16

OT

All other
bits

Not used

Query example

:STATus:QUEStionable:CONDition?
>1
Indicates an over voltage (OV) error has occurred.