beautypg.com

Error messages – GW Instek PEL-3000 Series Programming Manual User Manual

Page 162

background image

PEL-3000 Programming Manual

160

Error Messages

The following error messages may be encountered when reading
the error queue.

Error Code and string

Description

Command Errors

0 NoError

No error

-100 Command Error

This is the generic syntax error
for devices that cannot detect
more specific errors.

-101 Invalid character

A syntactic element contains a
character which is invalid for that
type.

-102 Syntax error

An unrecognized command or
data type was encountered.

-103 Invalid separator

The parser was expecting a
separator and encountered an
illegal character.

-104 Data type error

The parser recognized a data
element different than the one
allowed.

-105 GET not allowed

A Group Execute Trigger was
received within a program
message.

-108 Parameter not allowed

More parameters were received
than expected for the header.

-109 Missing parameter

Fewer parameters were received
than required for the header.

-110 Command header error

An error was detected in the
header.