beautypg.com

Measurement commands, Measure:current, Measure:voltage – GW Instek PEL-3000 Series Programming Manual User Manual

Page 41: Measure:power

background image

COMMNAND OVERVIEW

39

Measurement Commands

:MEASure:CURRent? .......................................................... 39

:MEASure:VOLTage? .......................................................... 39
:MEASure:POWer? .............................................................. 39

:MEASure:ETIMe? ............................................................... 40

:MEASure:CURRent?

Set

Query

Description

This command returns the load current.

Query Syntax

:MEASure:CURRent?

Return parameter

Load current in amps

Query example

:MEASure:CURRent?
>0.79860
Returns the load current in amps.

:MEASure:VOLTage?

Set

Query

Description

This command returns the load voltage.

Query Syntax

:MEASure:VOLTage?

Return parameter

Load voltage in volts

Query example

:MEASure:VOLTage?
>1.49900
Returns the load voltage in volts.

:MEASure:POWer?

Set

Query

Description

This command returns the power.

Query Syntax

:MEASure:POWer?

Return parameter

Power in watts

Query example

:MEASure:POWer?
>1.19695