beautypg.com

Current:frequency, Current:duty – GW Instek PEL-3000 Series Programming Manual User Manual

Page 79

background image

COMMNAND OVERVIEW

77

:CURRent:FREQuency

Set

Query

Description

Sets the CC dynamic mode switching frequency.
This command along with the “:CURRent:DUTY”
command is used when the dynamic time setting
is set to “Freq./Duty”.
This command is only applicable for dynamic
mode.

Syntax

:CURRent:FREQuency { | MINimum |
MAXimum}

Query Syntax

:CURRent:FREQuency?

Related
Commands

:CURRent:DUTY

Parameter

Sets the switching
frequency in hertz.

MINIMUM or MIN

Minimum frequency

MAXIMUM or MAX

Maximum frequency

Return parameter

Returns the frequency in
hertz.

Example

:CURRent:FREQuency 60
Sets frequency to 60Hz.

Query example

:CURRent:FREQuency?
>60
Returns the switching frequency (60Hz).

:CURRent:DUTY

Set

Query

Description

Sets the positive duty cycle for the CC dynamic
mode switching frequency. This command along
with the “:CURRent:FREQuency” command is
used when the dynamic time setting is set to
“Freq./Duty”.
This command is only applicable for dynamic