beautypg.com

Fsequence:edit:point – GW Instek PEL-3000 Series Programming Manual User Manual

Page 126

background image

PEL-3000 Programming Manual

124

Parameter

Parameters in order:

Description

Current step number

Total number of steps

Value

|OFF|ON

TRIG OUT setting

Return parameter

Returns the settings for
the Data Edit for Fast
Sequence menu:
Step:/,
Value:, TRIG
OUT:ON|OFF

Example

:FSEQuence:EDIT 4,11,0.1,OFF
Configures the Data Edit for Normal Sequence menu
to the settings shown below.

Query example

:FSEQuence:EDIT?
> Step:0004/0011; Value:0.10000, TRIG OUT:OFF

:FSEQuence:EDIT:POINt

Set

Query

Description

Sets or queries the current point in the sequence.

Syntax

:FSEQuence:EDIT:POINt {}

Query Syntax

:FSEQuence:EDIT:POINt?

Related
Commands

:FSEQuence:EDIT:END?

Parameter/
Return parameter

1~1000*. The current point in the
sequence. *Depends on the number
of steps in the sequence.

Example

:FSEQuence:EDIT:POINt 10
Sets the current point to 10.

Query example

:FSEQuence:EDIT:POINt?
>10