PEL-3000 Programming Manual

48

[:CONFigure]:CRUNit

Set

Query

Description

Sets or queries the CR mode setting units.

Syntax

[:CONFigure]:CRUNit {OHM|MHO}

Query Syntax

[:CONFigure]:CRUNit?

Parameter/
Return parameter

OHM

Set the units to ohms.

MHO

Set the units to mho
(conductance)

Example

:CRUNit OHM
Sets the CR mode units to ohms.

Query example

:CRUNit?
>OHM
The CR mode units are ohms.

:CONFigure:DYNamic

Set

Query

Description

Sets the display units for when dynamic mode
switching is used. Units can be selected from
Percent and Value. See the user manual for further
details. This command will also configure whether
to switch between each level using timers or a set
duty cycle.

Syntax

:CONFigure:DYNamic { VALue | PERCent | TIME |
FDUTy }

Query Syntax

:CONFigure:DYNamic?

Parameter

VALUE or VAL

Set the units to Value.

PERCENT or PERC

Set the units to Percent.

TIME

Use timers for timing.

FDUTY or FUDT

Use duty cycle for timing.

Return parameter

Return a string containing
the unit mode and the
timing mode.

Example

:CONFigure:DYNamic VALue
Sets the dynamic mode units to value.