COMMNAND OVERVIEW

83

Syntax

:RESistance:SET { | MINimum | MAXimum }

Query Syntax

:RESistance:SET?

Related
Commands

:RESistance:LEVel

Parameter

“Set” conductance value

MINIMUM or MIN

Minimum conductance
level

MAXIMUM or MAX

Maximum conductance
level

Return parameter

Returns the “Set”
conductance value.

Example

:RESistance:SET MIN
Sets the conductance to the minimum.

Query example

:RESistance:SET?
>.200
Returns the “Set” conductance setting in MHO.

:RESistance:LEVel

Set

Query

Description

Sets or queries the CR mode % level (percentage of
the Set conductance value) when the dynamic
mode units are set to Percent.

Syntax

:RESistance:LEVel { | MINimum | MAXimum }

Query Syntax

:RESistance:LEVel?

Related
Commands

:RESistance:SET

Parameter

“% level” conductance
value

MINIMUM or MIN

Minimum % conductance
level

MAXIMUM or MAX

Maximum % conductance
level

Return parameter

Returns the “% level”
conductance value.