COMMNAND OVERVIEW

29

*OPC

Set

Query

Description

This command sets the OPC (Operation Command
Bit) bit (bit 0) of the Standard Event Status Register
after the instrument has completed all pending
operations. The query will return the status of the
OPC bit.

Syntax

*OPC

Query Syntax

*OPC?

Return parameter

1

Operation complete

Query Example

*OPC?
>1
Indicates that all pending operations are complete.

*RCL

Set

Description

The Recall Instrument State command restores the
instrument settings from a previously saved
memory setting.

Syntax

*RCL

Parameter

1~256

Memory number 1 to 256

Example

*RCL 20
Recall setting memory 20.

*RST

Set

Description

Resets the unit. This is command forces the
ABORt, and *CLS

Syntax

*RST