beautypg.com

Configure]:gng:spectest, Configure]:gng:dtime – GW Instek PEL-3000 Series Programming Manual User Manual

Page 52

background image

PEL-3000 Programming Manual

50

TOGGLE or TOGG

Sets the button
configuration to toggle

Return parameter Toggle

Toggle

Hold

Hold

Example

:CONFigure:SHORt TOGGle
Sets the Short key configuration to toggle.

Query example

:CONFigure:SHORt?
>Toggle
The Short key is configured to toggle.

[:CONFigure]:GNG:SPECtest

Set

Query

Description

Enables/Disables Go-NoGo testing (SPEC test =
ON/SPEC test = OFF).

Syntax

[:CONFigure]:GNG:SPECtest {|OFF | ON }

Query Syntax

[:CONFigure]:GNG:SPECtest?

Parameter/
Return parameter

OFF or 0

SPEC test = OFF

ON or 1

SPEC test = ON

Example

:GNG:SPECtest ON
Turns Go-NoGo testing on.

Query example

:GNG:SPECtest?
>OFF
Indicates that Go-NoGo testing is off.

[:CONFigure]:GNG:DTIMe

Set

Query

Description

Sets or queries the Go-NoGo delay time.

Syntax

[:CONFigure]:GNG:DTIMe {[s] | MINimum
|MAXimum }

Query Syntax

[:CONFigure]:GNG:DTIMe?

Parameter

[s]

Sets the Go-NoGo delay
time in seconds (0.0~1.0)
with 0.1 second resolution.

MINIMUM or MIN

Minimum delay time

MAXimum or MAX

Maximum delay time