beautypg.com

Configure]:von, Configure]:vdelay – GW Instek PEL-3000 Series Programming Manual User Manual

Page 47

background image

COMMNAND OVERVIEW

45

[:CONFigure]:VON

Set

Query

Description

Sets or queries the Von voltage settings.

Syntax

[:CONFigure]:VON {[ V ] | MINimum|
MAXimum | LON | LOFF }

Query Syntax

[:CONFigure]:VON?

Parameter

{[ V ]

The Von voltage level
(default unit is V)

MINIMUM or MIN

Minimum Von voltage
level

MAXIMUM or MAX

Maximum Von voltage
level

LON

Latch on

LOFF

Latch off

Return parameter

Returns the Von latch
settings.

Example

:VON 10.0V
Sets the Von voltage to 10.0 volts.

Query example

:VON?
>Latch OFF, 10.000
The Von voltage level is 10V.

[:CONFigure]:VDELay

Set

Query

Description

Sets or queries the Von Delay settings in seconds.

Syntax

[:CONFigure]:VDELay {[s] | MINimum |
MAXimum | OFF }

Query Syntax

[:CONFigure]:VDELay?

Parameter

[s]

The delay time in seconds

OFF

Disable the delay time

MINIMUM or MIN

Minimum delay time

MAXIMUM or MAX

Maximum delay time

Return parameter

Returns the delay time in
seconds