beautypg.com

Mode]:dynamic – GW Instek PEL-3000 Series Programming Manual User Manual

Page 71

background image

COMMNAND OVERVIEW

69

Parameter

FAST

Fast response

SLOW

Slow response

Return parameter

Returns CV response
speed as a string.

Example

:RESPonse FAST
Sets the CV response to fast.

Query example

:RESPonse?
> CV mode response:FAST.

[:MODE]:DYNamic

Set

Query

Description

Sets or queries the switching mode. Dynamic is the
default mode.

Syntax

:MODE:DYNamic{ DYNamic | STATic }

Query Syntax

:MODE:DYNamic?

Parameter

DYNAMIC or DYN

Set to Dynamic mode

STATIC or STAT

Set to Static mode

Return parameter

Returns the switching
mode.

Example

:MODE:DYNamic DYN?
Set the switching mode to dynamic

Query example

:MODE:DYNamic?
> Dynamic, ;Dynamic Level:Value, Dynamic
Time:T1/T2
The switching mode is set to dynamic mode.